Lasershow Converter FLASH's default settings assume that:
If you are using differently-tuned scanners, or a different scan rate, then you need to make some adjustments. But first, some background.
The ILDA 30K tuning standard says that your scanners can show the ILDA Test Pattern in a specific way (circle touching the sides of the square), when the ILDA Test Pattern is displayed at 30,000 points per second:
Scanning too slow: Circle outside of square | Scanning too fast: Circle can't touch square | Scanning correctly: Circle touches midpoint of square |
The ILDA 30K speed is used when tuning. It does not mean that all frames must be shown at 30,000 pts/sec. Now, some people may adopt a scan speed of 30,000 points per second. In fact, this is Pangolin's suggestion. But you do not have to do this.
So there are two cases: You tune and project at 30,000 points per second, or you prefer other speeds for tuning and/or projection.
Pangolin suggests that all LD2000 users be using ILDA 30K-tuned scanners, AND that images be projected at 30,000 points per second.
Lasershow Converter FLASH's default settings follow this recommendation. You can find these default settings by looking in the picture on the Object Point Spacing topic page.
You may have frames or shows which require a different tuning or projection speed. If so, there are five ways in which you can adjust for this:
Lasershow Converter FLASH gives the best results if your scanners are tuned perfectly, and the bearings are in good shape. Please make sure that the low frequency damping and high frequency damping are adjusted properly for “critical damping.” Pangolin recommends ScannerMAX Saturn-series scanners for best results.